Initialisation file sch.iniΒΆ
The initialisation file sch.ini is used to save some schematic/symbols parameters. The file will be stored in the designs directory, if there is a design active.
If the schematic editor has been started as stand alone, the search rules for sch.ini will be as follows. When the last subdirectory name of the full edit path is sch or sym, the schematic editor will use the one level up directory. An example:
Symbols pull path:c:\design\test\sym\testsymbol.sym
The schematic editor is looking for the sch.ini in the c:\design\test directory. This situation is the case when a symbol or schematic from a design will be opened.
When there is no sch or sym directory, or the sch.ini does not exist, the schematic editor tries to find the sch.ini in the same directory as the symbol or sheet.
The following paramaters in the sch.ini are used:
[Files]
<The last used symbol/sheet files>
[Settings]
WindowWidth | The width of the windows |
WindowHeight | The height of the windows |
WindowStartX | Origin X of the windows (0,0 = left top) |
WindowStartY | Origin Y of the windows |
SymbolDialogStartX | Origin X of the add symbol dialog window |
SymbolDialogStartY | Origin Y of the add symbol dialog window |
GeometryDialogInitialX | Origin X of the dialog window geometrie selection |
GeometryDialogInitialY | Origin Y of the dialog window geometrie selection |
GeomScreenWidth | The width of the geometrie editor window |
GeomScreenHeight | The height of the geometrie editor window |
GeomStartX | Origin X of the geometrie editor window (0,0 = left top) |
GeomStartY | Origin Y of the geometrie editor window |
WireBusSelectMode | (0 = off,1 = on) |
Repeat mode | (0 = off,1 = on) |
LineSelectMode | (0 = normal, 1 = extended) |
SelectMode | (0 = Appending,1 = Replacement) |
DrawGrid | (0 = off,1 = on) |
GridSize | The gridsize (0.1,0.2,1.0) |
CrossHairVisible | (0 = off,1 = on) |
ButtonInfoTimeout | Maximum time popup display with component/net info is visible (100msec increments) |
PopupDisplayVisible | Popup display with component/net infois visible (0=off,1=on) |
BackGroundColor | 24 bit RGB color (Stored as 32 bit) |
WireColor | 24 bit RGB color (Stored as 32 bit) |
BusColor | 24 bit RGB color (Stored as 32 bit) |
BusConnectionColor | 24 bit RGB color (Stored as 32 bit) |
GlobalConnectionColor | 24 bit RGB color (Stored as 32 bit) |
JunctionColor | 24 bit RGB color (Stored as 32 bit) |
NetLabelColor | 24 bit RGB color (Stored as 32 bit) |
InstanceRefTextColor | 24 bit RGB color (Stored as 32 bit) |
InstanceValueTextColor | 24 bit RGB color (Stored as 32 bit) |
SymbolPinColor | 24 bit RGB color (Stored as 32 bit) |
SymbolPinBusColor | 24 bit RGB color (Stored as 32 bit) |
SymbolPinTextColor | 24 bit RGB color (Stored as 32 bit) |
SymbolPowerPinTextColor | 24 bit RGB color (Stored as 32 bit) |
SymbolPinBusTextColor | 24 bit RGB color (Stored as 32 bit) |
SymbolLineColor | 24 bit RGB color (Stored as 32 bit) |
SymbolRectColor | 24 bit RGB color (Stored as 32 bit) |
SymbolTextColor | 24 bit RGB color (Stored as 32 bit) |
SymbolArcColor | 24 bit RGB color (Stored as 32 bit) |
SymbolCircleColor | 24 bit RGB color (Stored as 32 bit) |
ObjectLineColor | 24 bit RGB color (Stored as 32 bit) |
ObjectRectColor | 24 bit RGB color (Stored as 32 bit) |
ObjectCircleColor | 24 bit RGB color (Stored as 32 bit) |
ObjectArcColor | 24 bit RGB color (Stored as 32 bit) |
ObjectTextColor | 24 bit RGB color (Stored as 32 bit) |
ButtonInfoColor | 24 bit RGB color (Stored as 32 bit) |
GridColor | 24 bit RGB color (Stored as 32 bit) |
[Printer]
PrinterName | Default printer name |
Options |